法规速查Regulation Navigator

先看懂要求,再查清依据。Understand the rule. Find its source.

试试Try
支持中文、英文和法规条号Chinese, English and citations

部分资料含历史版本或来源限制。收录日期不代表现行性已复核;请先核对每项官方来源、版本和适用范围。Some records contain historical versions or source limitations. Capture dates do not establish a review of current requirements; check each official source, edition and scope before use.

法规索引Regulation index

按中文名称了解每条管什么,再展开查看解读与官方原文。Browse by subject, then expand an entry for available explanations and official text.

清除全部条件Clear all filters
显示 3 / 248 条Showing 3 of 248 entries
轮胎要求§ 393.75 Tires.§ 393.75 Tires.轮胎要求
联邦49 CFR 393.75含中文解读With explanation
车灯正常工作与反光装置不受遮挡§ 393.9 Lamps operable, prohibition of obstructions of lamps and reflectors.§ 393.9 Lamps operable, prohibition of obstructions of lamps and reflectors.车灯正常工作与反光装置不受遮挡
联邦49 CFR 393.9含中文解读With explanation
动力车辆应配备的应急设备§ 393.95 Emergency equipment on all power units.§ 393.95 Emergency equipment on all power units.动力车辆应配备的应急设备
联邦49 CFR 393.95含中文解读With explanation
适用范围Scope

适用于联邦 Part 393 覆盖的货车和牵引车。本文选择常见检查项目,不替代完整出车检查、维修标准或特定车辆例外。For trucks and truck tractors covered by federal Part 393. These are common inspection points, not a replacement for the full pre-trip inspection, maintenance requirements or vehicle-specific exceptions.

按运输业务选择应急设备,并正确固定Match emergency equipment to the operation

CTAC 白话解读CTAC PLAIN-LANGUAGE EXPLANATION
具体要求What the rule requires
未用于运送危险品的动力车辆,通常至少配备一只 5 B:C 灭火器,或两只各为 4 B:C 的灭火器;运输达到贴牌数量的危险品时,动力车辆至少须配 10 B:C 灭火器。灭火器须充装充足、方便取用并牢固固定。警示装置可选择三只合格的双向反光三角牌,普通手电不能作为法定替代品。A power unit not used to transport hazardous materials generally needs one extinguisher rated at least 5 B:C or two rated at least 4 B:C each; a power unit carrying placardable hazardous materials needs at least 10 B:C. Keep extinguishers charged, accessible and securely mounted. Three compliant bidirectional reflective triangles are a permitted warning-device option; an ordinary flashlight is not a substitute.
条件与例外Conditions and exceptions
本条有 driveaway-towaway 等例外,并对特定危险品和燃气车辆携带火焰警示装置作限制。This section includes driveaway-towaway exceptions and restricts flame-producing warning devices on specified hazardous-material and compressed-gas vehicles.

Each truck, truck tractor, and bus (except those towed in driveaway-towaway operations) must be equipped as follows:

(a) (a) Fire extinguishers—(1) Minimum ratings. (i) A power unit that is used to transport hazardous materials in a quantity that requires placarding (See § 177.823 of this title) must be equipped with a fire extinguisher having an Underwriters' Laboratories rating of 10 B:C or more.

(ii) A power unit that is not used to transport hazardous materials must be equipped with either:

(A) A fire extinguisher having an Underwriters' Laboratories rating of 5 B:C or more; or

(B) Two fire extinguishers, each of which has an Underwriters' Laboratories rating of 4 B:C or more.

(2) Labeling and marking. Each fire extinguisher required by this section must be labeled or marked by the manufacturer with its Underwriters' Laboratories rating.

(3) Visual Indicators. The fire extinguisher must be designed, constructed, and maintained to permit visual determination of whether it is fully charged.

(4) Condition, location, and mounting. The fire extinguisher(s) must be filled and located so that it is readily accessible for use. The extinguisher(s) must be securely mounted to prevent sliding, rolling, or vertical movement relative to the motor vehicle.

(5) Extinguishing agents. The fire extinguisher must use an extinguishing agent that does not need protection from freezing. Extinguishing agents must comply with the toxicity provisions of the Environmental Protection Agency's Significant New Alternatives Policy (SNAP) regulations under 40 CFR Part 82, Subpart G.

(6) Exception. This paragraph (a) does not apply to the driven unit in a driveaway-towaway operation.

(f) (f) Warning devices for stopped vehicles. Except as provided in paragraph (g) of this section, one of the following options must be used:

(f)(1) (1) Three bidirectional emergency reflective triangles that conform to the requirements of Federal Motor Vehicle Safety Standard No. 125, § 571.125 of this title; or

(f)(2) (2) At least 6 fusees. The vehicle must have as many additional fusees as are necessary to satisfy the requirements of § 392.22 of this chapter.

(f)(3) (3) Other warning devices may be used in addition to, but not in lieu of, the required warning devices, provided those warning devices do not decrease the effectiveness of the required warning devices.

(g) (g) Restrictions on the use of flame-producing devices. Fusees or any other signal produced by a flame shall not be carried on any commercial motor vehicle transporting Division 1.1, 1.2, 1.3 (explosives) hazardous materials; any cargo tank motor vehicle used for the transportation of Division 2.1 (flammable gas) or Class 3 (flammable liquid) hazardous materials whether loaded or empty; or any commercial motor vehicle using compressed gas as a motor fuel.

阅读完整条文(英文)Read the full section (English)

使用固定来源版次;适用日期与例外以原文及历史沿革为准。Uses a fixed source edition; check the original and statutory history for operative dates and exceptions.

查看完整主题与例子Read the full topic and example

法规原文 · 英文REGULATION TEXT · ENGLISH

动力车辆应配备的应急设备§ 393.95 Emergency equipment on all power units.

来源Source:www.ecfr.gov49 CFR 393.95
前往官方网站Open official website

官方来源快照;不代表已核对现行汇编及后续修订。请核对来源版本。Official-source snapshot; current consolidated law and subsequent amendments have not been verified.

展开英文原文Read the English original收起英文原文Hide the English original

49 CFR 393.95 · § 393.95 Emergency equipment on all power units.

§ 393.95 Emergency equipment on all power units.

Each truck, truck tractor, and bus (except those towed in driveaway-towaway operations) must be equipped as follows:

(a)Fire extinguishers—(1) Minimum ratings. (i) A power unit that is used to transport hazardous materials in a quantity that requires placarding (See § 177.823 of this title) must be equipped with a fire extinguisher having an Underwriters' Laboratories rating of 10 B:C or more.

(ii) A power unit that is not used to transport hazardous materials must be equipped with either:

(A) A fire extinguisher having an Underwriters' Laboratories rating of 5 B:C or more; or

(B) Two fire extinguishers, each of which has an Underwriters' Laboratories rating of 4 B:C or more.

(2) Labeling and marking. Each fire extinguisher required by this section must be labeled or marked by the manufacturer with its Underwriters' Laboratories rating.

(3) Visual Indicators. The fire extinguisher must be designed, constructed, and maintained to permit visual determination of whether it is fully charged.

(4) Condition, location, and mounting. The fire extinguisher(s) must be filled and located so that it is readily accessible for use. The extinguisher(s) must be securely mounted to prevent sliding, rolling, or vertical movement relative to the motor vehicle.

(5) Extinguishing agents. The fire extinguisher must use an extinguishing agent that does not need protection from freezing. Extinguishing agents must comply with the toxicity provisions of the Environmental Protection Agency's Significant New Alternatives Policy (SNAP) regulations under 40 CFR Part 82, Subpart G.

(6) Exception. This paragraph (a) does not apply to the driven unit in a driveaway-towaway operation.

(b)-(e) [Reserved]

(f)Warning devices for stopped vehicles. Except as provided in paragraph (g) of this section, one of the following options must be used:

(f)(1)Three bidirectional emergency reflective triangles that conform to the requirements of Federal Motor Vehicle Safety Standard No. 125, § 571.125 of this title; or

(f)(2)At least 6 fusees. The vehicle must have as many additional fusees as are necessary to satisfy the requirements of § 392.22 of this chapter.

(f)(3)Other warning devices may be used in addition to, but not in lieu of, the required warning devices, provided those warning devices do not decrease the effectiveness of the required warning devices.

(g)Restrictions on the use of flame-producing devices. Fusees or any other signal produced by a flame shall not be carried on any commercial motor vehicle transporting Division 1.1, 1.2, 1.3 (explosives) hazardous materials; any cargo tank motor vehicle used for the transportation of Division 2.1 (flammable gas) or Class 3 (flammable liquid) hazardous materials whether loaded or empty; or any commercial motor vehicle using compressed gas as a motor fuel.

(h)-(i) [Reserved]

(j)Requirements for fusees. Each fusee shall be capable of burning for 30 minutes. Fusees shall conform to the requirements of Underwriters Laboratories, Inc., UL No. 912, Highway Emergency Signals, Fourth Edition, July 30, 1979, (with an amendment dated November 9, 1981). (See § 393.7 for information on the incorporation by reference and availability of this document.) Each fusee shall be marked with the UL symbol in accordance with the requirements of UL 912.

(k)Requirements for red flags. Red flags shall be not less than 12 inches square, with standards adequate to maintain the flags in an upright position.

[33 FR 19735, Dec. 25, 1968, as amended at 35 FR 13019, Aug. 15, 1970; 35 FR 14619, Sept. 18, 1970; 37 FR 17176, Aug. 25, 1972; 40 FR 10685, Mar. 7, 1975; 41 FR 53031, Dec. 3, 1976; 47 FR 47837, Oct. 28, 1982; 59 FR 34712, July 6, 1994; 67 FR 61225, Sept. 27, 2002; 70 FR 48054, Aug. 15, 2005; 72 FR 44036, Aug. 7, 2007; 78 FR 58484, Sept. 24, 2013; 80 FR 59075, Oct. 1, 2015; 91 FR 7870, Feb. 19, 2026; 91 FR 7880, Feb. 19, 2026]

来源版本日期Source edition date 2026-10-08收录日期Captured 2026-10-12

全文按此版本留存;来源更新后保留旧版,主题解读仍以所标版本为准。This is the stored edition. Earlier editions are retained; topic explanations refer to their stated edition.

依据关联的官方原文及官方项目说明起草。中文和英文解读均为 CTAC AI 辅助工作稿,未经人工审核;教学案例不是实际会员记录。采集日期不是法规生效日期。Drafted from linked official texts and agency guidance. Both language interpretations are CTAC AI-assisted drafts pending human review; examples are illustrative, not member records. Capture dates are not legal effective dates.

中文为 CTAC 白话说明,不是官方译文,也不构成个案法律意见。请先核对适用范围、来源版本与最新官方通知。CTAC plain-language explanations are not official translations or case-specific legal advice. Check scope, source editions and current official notices.